Jump to: ↓ Downloads

SINGLE 5 BAR GATE HUNG ON FACE OF POSTS

Hanging a single 5 Bar gate on the rear face of posts is a practical and traditional way to maximise the clear opening width of an entrance.  By fixing the gate to the rear face of the posts rather than between them, full access can be achieved while maintaining strength and stability. Correct installation is essential. A quality, well-made gate will only perform as intended if it is properly supported, aligned and fitted using the right hardware.

Gate hinge positions & gate fitting tolerances 

5 Bar gate hung on face of posts

A = Adjustable double strap field hinge set | B = Spring latch and keep set 

C = Hanging stile | D = Drop bolt (important if gate is to be left open)

 

Gates must be hung from the larger hanging stiles (C) unless it is a universal gate with both stiles the same size.

A minimum of 50mm ground clearance should be allowed when hanging the gate.

As the gate and posts are a natural material, some movement may occur with changes in temperature and humidity. The hinges (A) can be adjusted to allow for seasonal movement in the timber.

Measurements are based on the fittings supplied by Charltons and are intended as a guide.  We recommend that gates are installed by an experienced professional.

Automated gates require a heavy-duty bottom rail, either flush or standard depending on the type of automation you are having. They should be installed and commissioned by a qualified gate automation specialist. Standard gate fittings should be suitable; however, please consult your automation specialist, as automated gates may require alternative fittings.

 

Gate opening

 The gate can open inwards towards property up to 180° (assuming no object blocks the swing of the gate). The gate should not open onto a public highway or pavement in accordance with the Highways Act 1980.

Single 5 Bar gate hung on face of posts opening

We do not recommend that the gate is left open for any length of time. If the gate is to be left in the open position, an extra socket should be fitted so that the drop bolt can be used to secure the gate whilst open, no more than 180° past the post so that the gate does not bend, excess pressure is not exerted on the hinges and cannot blow shut and cause injury. A drop bolt must be installed using the supplied socket set. Leaving the drop bolt loose, especially in gravel, can lead to the gate warping or being damaged.

Drop bolt & socket - gate left open

Gate hinge & fitting recommendations

Please note: For automated gates, standard gate fittings may be suitable; however, please consult your automation specialist, as automated gates may require alternative fittings.

Adjustable Field Gate Hinge Set for Pair 5 Bar gates hung on face of posts

Adjustable double strap field hinge set

Spring latch and keep set for field gates

Spring latch and keep set

Self locking field gate latch and D loop

Self locking field gate latch and D loop

Drop bolt and socket set

Drop bolt & socket set

Socket set for 5 bar gate

Extra Socket set if gate to be left open

Gate post recommendations

For most gates, particularly heavier designs, the gate posts should ideally be installed approximately 3ft (900mm) into the ground to provide adequate support. Posts set too shallow may become loose, move over time, or begin to lean, placing additional strain on the gate and its ironmongery. Shallow posts are also more susceptible to frost heave, where freezing ground conditions can gradually lift them out of position. To help prevent this, the post hole should be wider at the bottom than at the top, creating a bell-shaped footing that helps lock the concrete securely into the ground.

Gate post reccommendations for 5 bar gates

 

Gate automation

 5 Bar gates can be automated with the addition of a heavy-duty rail. This is required for the gate to withstand the stresses of the automation movement. 5 Bar gates can have a standard or a flush heavy-duty rail depending on the type of automation being used.

Automated gates must be installed by a fully qualified installer who must ensure it complies with the Supply of Machinery (Safety) Regulations 2008

As the owner of an automated gate, you are technically the owner of a machine, which just like your car requires routine maintenance. The gate should be checked over by a qualified installer every six months as a minimum.

More details can be found HERE

Gate treatment

 Pressure treatment provides protection against fungal decay and insect attack but does not prevent weathering caused by sunlight and moisture. The elements and UV rays will slowly degrade the effectiveness of the pressure treatment. Timber is a natural material and will expand, contract and move with changes in temperature and moisture levels. Minor twisting, bowing and surface cracking are normal characteristics of timber, not a manufacturing fault, and do not affect the structural integrity of the gate.

We recommend that all planed timber gates are treated with a modern UV Oil for planed timber such as Osmo (Softwood gates once they have thoroughly dried out). This is particularly important when hanging  5 Bar gates as it will help alleviate potential warping due to weathering and UV rays.

For more information please visit our treatment pages HERE

PLEASE NOTE: Timber is a natural material and will expand, contract and move with changes in temperature and moisture levels. Minor twisting, bowing and surface cracking are normal characteristics of timber and do not affect the structural integrity of the gate.

Gate maintenance

Manual gate maintenance

Best practice: Re-check hinge adjustment and gate clearances several weeks after installation as timber and new posts may settle.

Manual installations should be supported by a regular maintenance regime. The time intervals between maintenance checks will be largely determined by the amount of usage the gate is expected to tolerate. A low usage situation would represent up to 50 operations a day; low usage gates should be checked at least every 12 months. If there are any changes in the gate, for example, if the gate drags on the ground, this could be a sign that urgent attention is required to avoid compromising the safety of the gate.

Challenging weather conditions, such as high winds/gales and heavy rain can cause damage to a gate and/or affect the foundations. Routine checks should always be made once the bad weather has subsided. The following should be checked:

  • Review hinges for signs of excessive wear and tear e.g. damage, cracking
  • Check the foundations for any signs of movement
  • Look out for any indication that the material from which the gate has been crafted has in any way been compromised e.g. gates showing signs of excessive cracks
  • Check that all ancillary equipment e.g., drop bolts and catches are working as expected. Any component showing excessive wear or more than 15% damage , a replacement should be considered.

Automated gate maintenance

Automated gates must be installed by a fully qualified installer who must ensure it complies with the Supply of Machinery (Safety) Regulations 2008. As the owner of an automated gate, you are technically the owner of a machine, which just like your car requires routine maintenance. The gate should be checked over by a qualified installer every six months as a minimum.

More details can be found at Gate Safe

Download

SINGLE BAR GATE HUNG ON FACE OF POSTS ICON

 

Other guides to download

SINGLE BAR GATE HUNG BETWEEN POSTS
PAIR 5 BAR GATES HUNG ON FACE OF POSTS
PAIR 5 BAR GATES HUNG BETWEEN POSTS
DRIVEWAY GATES HUNG BETWEEN WALLS
PEDESTRIAN GATE HUNG BETWEEN WALLS
Side or garden gates hung between posts download Icon
seasonal gate maintenance icon
Treating your wooden gates
gate automation
measuring for a 5 Bar gate
MEASURING FOR A DRIVEWAY GATE
MEASURING FOR A PEDESTRIAN GATE ICON