PAIR OF 5 BAR GATES HUNG ON FACE OF POSTS

Hanging a pair of 5 Bar gates on the rear face of posts is a practical and traditional way to maximise the clear opening width of an entrance.  By fixing the gates to the rear face of the posts rather than between them, full access can be achieved while maintaining strength and stability. Correct installation is essential. Quality, well-made 5 Bar gates will only perform as intended if they are properly supported, aligned and fitted using the right hardware.

Gate hinge positions & gate fitting tolerances 

Pair of 5 Bar gates hung on face of posts - fittings

A = Adjustable double strap field hinge set | B = Loop over latch

C = Drop bolts & sockets (one for each gate) | D = Hanging stile

 Gates must be hung from the larger hanging stiles (D) unless it is a universal gate with both stiles the same size.

Pair of 5 Bar gates hung on face of posts fitting

Measurements are based on the fittings supplied by Charltons and are intended as a guide. We recommend that gates are installed by an experienced professional.

Automated gates require a heavy-duty bottom rail, either flush or standard depending on the type of automation you are having. They should be installed and commissioned by a qualified gate automation specialist. Standard gate fittings should be suitable; however, please consult your automation specialist, as automated gates may require alternative fittings.

As the gates and posts are a natural material, some movement may occur with changes in temperature and humidity. The hinges (A) can be adjusted to allow for seasonal movement in the timber.

 

Gate openings  

Gates can open inwards to the property up to 180° (assuming no objects are in the way).

Gates should not open onto a public highway or pavement in accordance with the Highways Act 1980.

Pair 5 Bar gates on face of post opening

 

We do not recommend that the gates are left open for any length of time. If the gates are to be left in the open position, extra sockets should be fitted so that the drop bolts can be used to secure the gates whilst open, no more than 180° past the post so that the gates do not bend, excess pressure is not exerted on the hinges, and they cannot blow shut and cause injury. Drop bolts must be installed using the supplied sockets. Leaving the drop bolts loose, especially in gravel, can lead to the gate warping or being damaged.

 

Pair 5 Bar gates hung on face of posts

Gate hinge & fitting recommendations

Adjustable Field Gate Hinge Set for Pair 5 Bar gates hung on face of posts

Adjustable Field Gate Hinge Set

Loop over latch for Pair 5 Bar gates

Loop over latch

Drop bolt and socket set

Drop bolt & socket set

Drop bolt socket set

Extra socket set

Gate post recommendations

For most gates, particularly heavier designs, the gate posts should ideally be installed approximately 3ft (900mm) into the ground to provide adequate support. Posts set too shallow may become loose, move over time, or begin to lean, placing additional strain on the gate and its ironmongery. Shallow posts are also more susceptible to frost heave, where freezing ground conditions can gradually lift them out of position. To help prevent this, the post hole should be wider at the bottom than at the top, creating a bell-shaped footing that helps lock the concrete securely into the ground.

 

Gate post reccommendations for 5 bar gates

 

Gate automation

5 Bar gates can be automated with the addition of a heavy-duty bottom rail. This is required for the gate to withstand the stresses of the automation movement. 5 Bar gates can have a standard or a flush heavy duty bottom rail depending on the type of automation being used.

Automated gates must be installed by a fully qualified installer who must ensure the installation complies with the Supply of Machinery (Safety) Regulations 2008

As the owner of an automated gate, you are technically the owner of a machine, which just like your car requires routine maintenance. The gate should be checked over by a qualified installer every six months as a minimum.

More details can be found HERE

Gate Treatment

Pressure treatment provides protection against fungal decay and insect attack but does not prevent weathering caused by sunlight and moisture. The elements and UV rays will slowly degrade the effectiveness of the pressure treatment. Timber is a natural material and will expand, contract and move with changes in temperature and moisture levels. Minor twisting, bowing and surface cracking are normal characteristics of timber and do not affect the structural integrity of the gate.

We recommend that all planed timber gates are treated with a modern UV Oil for planed timber such as Osmo (Softwood gates once they have thoroughly dried out). This is particularly important when hanging 5 Bar gates as it will help alleviate potential warping due to weathering and UV rays. 

For more information, please visit our treatment pages HERE

 

Gate Maintenance

Manual Gate Maintenance

Manual installations should be supported by a regular maintenance regime. The time lapses between maintenance checks will be largely determined by the amount of usage the gate is expected to tolerate. A low usage situation would represent up to 50 operations a day. Low usage gates should be checked every at least every 12 months. If there are any changes in the gate, for example, if the gate drags on the ground, this could be a sign that urgent attention required to avoid compromising the safety of the gate.

Challenging weather conditions, such as high winds/gales and heavy rain can cause damage to a gate and/or affect the foundations. Routine checks should always be made once the bad weather has subsided. The following should be checked:

  • Review hinges for signs of excessive wear and tear e.g. damage, cracking
  • Check the foundations for any signs of movement
  • Look out for any indication that the material from which the gate has been crafted has in any way been compromised e.g. gates showing signs of excessive cracks
  • Check that all ancillary equipment e.g., drop bolts and catches are working as expected. If any is classed as featuring in excess of 15% damage, a replacement should be considered

Automated Gate Maintenance

Automated gates must be installed by a fully qualified installer who must ensure it complies with the Supply of Machinery (Safety) Regulations 2008

As the owner of an automated gate, you are technically the owner of a machine, which just like your car requires routine maintenance. The gate should be checked over by a qualified installer every six months as a minimum.

More details can be found at Gate Safe

Download

DRIVEWAY GATES HUNG BETWEEN WALLS

Other guides to download

Driveway gates hung between walls download icon
Pair of 5 Bar Gates hung on face of posts download icon
Pair of 5 Bar gates hung between pots download icon
Single-5 Bars gate hung on face of posts icon
SINGLE BAR GATE HUNG BETWEEN POSTS
PEDESTRIAN GATE HUNG BETWEEN WALLS DOWNLOAD ICON
PEDESTRIAN GATE HUNG BETWEEN POSTS DOWNLOAD ICON
gate automation icon
seasonal gate maintenance icon
Treating your wooden gates DOWNLOAD ICON
How to measure for a 5 Bar gate icon
How to measure for a 5 Bar gate icon
MEASURING FOR A PEDESTRIAN GATE DOWNLOAD ICON